STT Flow Tester
STT Flow Tester
Standard Leak
High Precision DP Sensor
High Precision Regulating Valve
CPU: NXP QUAD CORE I.MX6Q/NXP DUAL CORE I.MAX6DL
Framework: CORTEX-A9
Frequency: 1GHz
Memory: 1GB DDR3 / 2GB DDR3
ROM: 8GB EMMC
Storage USB Flash Disk
7.0-Inch True-color Touch Screen With 1024 * 600 Resolution
Product Feature
Parameter
Installation Dimension
STT Flow Tester is especially suitable for automatic and semi-automatic worktables,
allowing leakage flow test with large leakage and valve body switching flow test.
The principle is that the reference part and the test part are filled with the same pressure.
Because the test part leaks to the atmosphere, test the leakage flow of the reference part to the test part,
deduce the leakage flow of the test part, and also test the flow test when the valve body is opened.
STT Flow Tester adopts mass flow sensor. The measured mass flow is very little affected by ambient pressure and temperature.
It can provide more stable measurement and is widely used in industrial field.
It Can Meet Various "Leak Detection Needs"
Recordable data
Quantification of leakage
Keep the test article clean
Improve working environment
Easy to operate
Shorten test time
Reduce complaints
Reduce additional consumption
No dry work required
Method | Flow Tester | |
Flow Range | 0%~100FS, Accuracy: ±1% S.P(30%FS <=), ±0.3%FS(<30%FS) | |
Pressure Testing Range | Range: 0~1000KPa, Accuracy: ±2%FS, Resolution: 0.1%FS | |
Range: 0~100KPa, Accuracy: ±2%FS, Resolution: 0.1%FS | ||
Display | 7-inch capacitive touch screen display | |
Resolution:1024×600,Size:W154mm×D86mm | ||
Display Unit | Test Pressure | KPa,MPa,bar,psi |
Leakage | mL/min, L/min | |
Time Setting | 999.9sec( Resolution:0.1sec) | |
Pressure | 1MPa | |
Language | Chinese & English | |
Ambient Temperature | 5~40℃ | |
Accuracy Guarantee Temperature | 15~35℃ | |
No.of Programs | Up to 128 Programs | |
Rear Rerminal I/O | Input Signal:9, Output Signal:9 | |
External Solenoid Valve Control Signal:9 | ||
Rear Terminal Capacity | External input: the maximum voltage of each node is 10mA and the maximum voltage is 30V | |
External output: the maximum voltage of each node is 200mA and the total current is 1A | ||
External solenoid valve:the maximum voltage of each node is 0.5A and the total current is 1A | ||
Range of Temperature and Humidity | 0~40 ℃ 45~85%RH No condensation | |
CPU | Cortex-A9 1GHZ(DRAM 1GB,ROM 8GB Emmc) | |
RS232C | (1) Output leakage data and set value at the same time | |
(2) Connect to printer and communicate with modbus RTU | ||
RJ45 | Communicate with rofibus,profinet,Ethernet/I,Modbus TCP ,devicenet | |
USB | (1) Data saving: result, leakage value, test, PR#, time, etc. | |
(2) Setpoint download CSV file | ||
(3) Connected to printer,code scanning grab,keyboard,mouse,USB and PC | ||
Supply Voltage | AC 100~240V,50/60Hz | |
Gas Source | 1.Driving Gas:400~700KPa | |
2.Solid particles and concentration level 4(40μm &10mg/m3) | ||
3.Dew point level 4(-40℃) | ||
4.Maximum oil concentration level 3(1.0mg/ m3) | ||
Consumption | ≤50W | |
Appearance Dimension | W362×H198×D340(mm) | |
Weight | 9kg | |
Enclosure | (1)power cord | |
(2)I / O connector, inspection report, operation manual, quality tracking certificate |